nbnCO FTTC (Fibre-to-the-Curb) Test Methods and Topology

We are here to assist you in understanding the nbnCO FTTC (Fibre-to-the-Curb) Testing requirements, providing specialised Test Equipment, Safety equipment, and Tools to Install and Maintain the nbnCO FTTC Fibre and Copper infrastructure and Network

TMG has supplied over million+ of solutions to NBN Telecommunication Contractors for the Installation and Maintenance of Telstra/nbnCO Copper Telephone lines, ADSL & VDSL services, FTTP (Fibre-to-the-Premises), FTTB (Fibre-to-the-Basement), FTTN (Fibre-to-the-Node), and FTTC (Fibre-to-the-Curb)

Network Topology

Breakout Joint Location (BJL)
Located in the Local Fibre Network (LFN)
Flexible Joint Location (FJL)
Distribution Joint Location (DJL)
Located in the Distribution Fibre Network (DFN)

Installation and Maintenance Testing Methods

When installing a new optical network it's imperative that a "baseline record" of optical link quality is recorded measuring optical loss characteristics of all links, and optical power levels. Creating a "baseline" results assist in maintaining, and troubleshooting issues that may arise after end users are connected to the network.

Testing Tools

Optical Time Domain Reflectometer (OTDR) Testing

In nbn’s Distribution Fibre Network (DFN) and Local Fibre Network (LFN), Uni-directional testing is performed using an Optical Time Domain Reflectometer (OTDR) to characterise the optical link at both 1310nm and 1625nm wavelengths.

An OTDR sends thousands of pulses of light into a fibre at these wavelengths to create a Trace. This trace shows “events” in optical cable, relating to optical length, splice loss, and “macro bending”.

So why test at both 1310nm and 1625nm wavelengths? By comparing the Trace of the 1310nm and 1625nm this highlights macro bending. Macrobend loss refers to losses induced in bends in the fibre predominately caused when manipulating the physical fibre inside splice closures – Breakout Joint Location (BJL), Flexible Joint Location (FJL) and Distribution Joint Location (DJL).

VIAVi Logo
VIAVI MTS-4000 Tri-band OTDR

The VIAVI MTS-4000 Tri-band OTDR includes 1310nm, 1550nm & 1625nm wavelengths to meet both NBN and Telstra OTDR fibre testing requirements.

Smart Link Mapper

The VIAVI Smart Link Mapper (SLM) comes as standard on the all VIAVI OTDRs and provides a block diagram overview of the trace. This excellent function helps the user breakdown the trace with icons for Splitters, connectors and bends.


The VIAVI MTS-2000 or MTS-4000 is the only OTDR currently on the market that will display the trace and SLM view on the screen at the same time.

Smart Assistant

The OTDR settings need to be changed depending on where you are testing on the Distribution or Local Fibre Network. Smart Assistant allows the user to select the section they are working on and will automatically configure the OTDR to the NBN documents.

Testing Through Splitters

The NBN Tester Architecture 3 Network now comprises of Splitters which are housed in the FJL, BJL or the SMP. These splitters can be problematic for taking OTDR traces. If the OTDR is only designed to test from point to point then you will have errors with the results given from the OTDR.

The Viavi MTS-2000 and MTS-4000 can be configured to test through the splitters allowing the user to test from the DPU all the way back to the exchange if required.

150m Launch Lead, Singlemode

The PH Palden LL-ECO-150M is an ideal 150m long launch lead with SC/A Singlemode connectors for your NBN OTDR testing needs

VIAVI MTS-2000 Tri-band OTDR

The VIAVI MTS-2000 Tri-band OTDR includes 1310nm, 1550nm & 1625nm wavelengths to meet both NBN and Telstra OTDR fibre testing requirements.

Launch Leads - What are they and why are they used?

Launch leads are an essential accessory to be used with the OTDR when testing a Fibre Network.

The launch lead places the Fibre under test far enough from the connector of the OTDR to prevent any errors caused by a possible dead zone.


For NBN a minimum of 150 metre Fibre Launch Lead must be used. and for 1,000 metres for other carriers such as Telstra.

Connecting to Optitap / Optitip ports for Testing

If you need to connect a PON meter or OTDR to the Multiport then you will need a OptiTap Adaptor. Your choice is a SCA/ HC Male and a SCA/ HC Female adapter.

OptiTap to SC/APC Adapter (FEMALE)
SC/APC to Optitap 2m Patch Lead (MALE)

PON (Passive Optical Network) Meter

Why and where are they used? 

Tests 1310 nm upstream, 1490/1550 nm downstream

VIAVI OLP-87-FTTC-BV PON Meter

The P5000i makes it fast and easy to certify that every connection in your network is clear and optimized


Easily connect to an OLP-87 PON Meter, MTS-2000 or MTS-4000 OTDR, HST-3000, ONX-580, ONX-620/630 or laptop/PC via USB without the need for any additional adapters.

Kingfisher KI6102AA-APC PON Meter

Good quality, ruggardised PON Meter.   This PON Meter will test 1310nm, and 1490/1550nm downstream wavelengths.

Fibre End Face Inspection

90% of faults in the fibre network are caused by bad connections.

This could be caused by a bad splice or a contaminated connector. As per the NBN document NBN-TE-CTO-376. It is vital; that the female and male sides of any fibre are cleaned and inspected (however new or old the fibre or connector is) before mating together or irreversible damage is caused causing more time and money to resolve.

For Fibre-to-the-Curb (FTTC), you will need to INSPECT ALL of the following;

  • the Ribbon 12F Optitip,
  • the Opti Tap Femaie / Male of the Bulkhead connector (see below), and
  • the single fibre SC/APC drop cable being terminated at the DPU.
Specialised Optitap and Optitip Inspection Probe Tips

VIAVI FBPT-COD-L
Tip, OptiTap Single Fibre for Fibre Inspection Probe

VIAVi Logo
VIAVI P5000i USB Fibre Connector Face Inspection Microscope

The P5000i makes it fast and easy to certify that every connection in your network is clear and optimized


Easily connect to an OLP-87 PON Meter, MTS-2000 or MTS-4000 OTDR, HST-3000, ONX-580, ONX-620/630 or laptop/PC via USB without the need for any additional adapters.


Fusion Splicing

Splicing is required at each Splitter in the Fibre in the Local Fibre Network (LFN) and Distribution Fibre Network (DFN) parts of the Network.


Whether you are splicing Ribbon Fibre in the Distribution Fibre Network (DFN) or the de-ribbonised Fibre in the Local Fibre Network (LFN) it is important to choose a splicer with high accuracy (Low Insertion Loss) and that is quick and easy to use.

Sumitomo Type-72C

High Definition Single Core Aligning Fusion Splicer

Local Fibre Network (LFN)

Single Core Alignment Splicing is required


To carry out splicing at the FJL or the BJL the Ribbon Fibre needs to be firstly de-ribbonised into single fibres.


Each Fibre needs to be prepared, cleaved, spliced with precision to ensure minimum loss over the splice.


The Sumitomo 72C (pictured) uses the latest in technology to line up the fibre with precision and will out the splice in seconds.

Sumitomo Type-71M

Mass Ribbon Fusion Splicer

Distribution Fibre Network (DFN)

Ribbon Splicing is required

The Sumitomo 71M Ribbon Splicer (pictured) is able to splice both ribbon and single core fibre.


This allows the user to Splice at the DJL using the 12 Ribbon Fibre Holder on at the FJL / BJL with the Single Fibre Holder.

FTTC Training and Instructional Videos

Video Series

FTTC OTDR Testing with the VIAVI (formerly JDSU) OTDRs

MTS-4000v2 OTDR Videos (FTTC/FTTP)

TMG Video Series for the VIAVI (formerly JDSU) OTDRs
This playlist currently contains the following videos:



OTDR Folder Instructions – nbn FTTC & FTTP

OTDR Set Up for NBN FTTC (DPU to FJL)

OTDR Training – Selecting the correct Pulse Width Setting for the MTM LFN



The OTDR Training video series is our way of continuing our commitment to providing the very best in technical support for our valued customers.

Video Series

Inspect Before You ConnectTM Training Videos

Inspect Before You ConnectTM Training Videos

This Video Series currently contains the following training videos:


⟹ Inspect Before You Connect Introduction

⟹ Proactive vs. Reactive Inspection

⟹ Importance of Inspecting BOTH Sides of a Connection

⟹ The Importance of Inspecting New Fibre Connectors

⟹ Cleaning Stick vs. a Clicker
⟹ Static Charge and Contamination

⟹ Understanding Fibre Cleaning Solvents

⟹ The Importance of Reliable Cleaning Tools

⟹ Understanding the IEC-61300-3-35 Standard

⟹ The Importance of Automated Pass/Fail Analysis for Fibre Inspection

⟹ The Importance of Documenting Fibre Inspection Results

⟹ The Importance of Investing in Inspection and Cleaning Today



These videos are presented by Tyler Vander Ploeg (VIAVI Solutions) and Brian Teague (MicroCare)

Glossary

BJLBreakout Joint
CSPContent Service Provider
DDDDetailed Design Documentation
DFNDistribution Fibre Network
FANFibre Access Node
FDHFibre Distribution Hub
FJLFlexible Joint Location
FTTNFibre to the Node
FTTBFibre to the Building
FTTCFibre to the Curb
HFOCHardened Fibre Optic Connector
IORIndex of Refraction
LFNLocal Fibre Network
MDUMulti-Dwelling Unit
MFDMode Field Diameter
MPTMultiport
MT-DFNMulti-Technology™ Distribution Fibre Network
MT-LFNMulti-Technology™ Local Fibre Network
MT-DFN/LFNMulti-Technology™ Distribution Fibre Network/Local Fibre Network
MTMMulti-Technology Mix
OTDROptical Time Domain Reflectometer
PCDPremises Connection Device
PONPassive Optical Network